Brand Name : EuroKlimat
Model Number : EKDM
Certification : ISO9001, ISO14001, OHSAS18001, CRAA, CQC
Place of Origin : China
MOQ : 1
Price : negotiation
Payment Terms : L/C, T/T
Supply Ability : 5,000pcs per month
Delivery Time : 15 working days after received your payment
Packaging Details : Plywood
Product Name : Double skin fresh air handling units
Installation : Ceiling/floor installation
Cooling Capacity(kW) : 25-300
Heating Capacity(kW) : 28-330
Air Flow(m3/h) : 5000-60000
Aluminum Fins : Shutter-type hyperbolic and hydrophilic fins
Test Pressure (Mpa) : 3.3
Coils rows : 4/6
Double skin fresh air handling units with 4-8 rows cooling coil air flow 2,000-400,000 m3h
EKDM air flow range is from 1000m3/h to 400000m3/h. Available functional sections include fresh/return air mixing section, cooling section, heating section, primary/medium/high efficiency filter section, electric heating section, humidifying section, sound attenuation section, heat recovery section, secondary air-return section, fan section, air diffuser section etc. Different combinations can meet different air handling requirements.
• The surface of the unit is made of quality color steel, which can resist corrosion, scratch and ultraviolet radiation.
•    Internal panels are made of steel plates galvanized  with aluminum and zinc, with an assured  service life of more than 15 years. All panels  feature  end-to-end  joints and smooth surfaces, without any bur or corroded point.
•    The internal panels feature reinforced design, which is strong enough to support the largest  air handling unit.
•    The unit panel  has two thicknesses,  namely  30mm and 50mm.Inside  the panel, hermetically foamed polyurethane (no fluorine) with a density of 48kg/m3 is used as the heat- insulating material. The heat conductivity factor is less than 0.02W/m°C.
•    Each functional section of the unit is equipped  with a steel trough base, thus  ensuring  it is well supported,  easy to transport and assemble. The overall robustness of the unit meets the  standard of CEN2.
The unit features a special clamp structure, facilitating disassembly and maintenance as well as ensuring low air leakage. When the internal negative pressure is 1000Pa, the air leakage is below 1% (level B air leakage of European standard EN1886).
• The unit panels are coated with strong and heat-insulating UPVC plastics, thus avoiding direct contact between heat-conductive parts. With a heat-insulation grade of T1 (European standard), thermal bridge and cooling capacity loss are completely eliminated.
Specifciations
| Unit model EKDM | Rated air flow m3/h | 4 rows | 6 rows | 8 rows | |||||||||
| Total cooling capacity kW | Water flow l/s | Water resi-stance kPa | Pipe diameter DN | Total cooling capacity kW | Water flow l/s | Water resi-stance kPa | Pipe diameter DN | Total cooling capacity kW | Water flow l/s | Water resi-stance kPa | Pipe diameter DN | ||
| 306 | 2000 | 29 | 1.3 | 30 | 40 | 34 | 1.6 | 23 | 40 | 39 | 1.8 | 38 | 40 | 
| 406 | 3000 | 42 | 2.0 | 34 | 40 | 50 | 2.4 | 28 | 40 | 57 | 2.8 | 46 | 40 | 
| 407 | 4000 | 53 | 2.6 | 27 | 40 | 68 | 3.2 | 52 | 40 | 74 | 3.5 | 44 | 40 | 
| 408 | 5000 | 67 | 3.2 | 43 | 40 | 82 | 4.0 | 51 | 50 | 89 | 4.2 | 18 | 50 | 
| 508 | 6000 | 82 | 3.9 | 29 | 50 | 101 | 4.9 | 34 | 50 | 114 | 5.5 | 51 | 50 | 
| 607 | 7000 | 90 | 4.3 | 25 | 50 | 116 | 5.5 | 51 | 65 | 129 | 6.2 | 45 | 50 | 
| 608 | 8000 | 107 | 5.1 | 36 | 65 | 132 | 6.3 | 41 | 65 | 143 | 7.0 | 26 | 50 | 
| 511 | 9000 | 124 | 6.0 | 44 | 65 | 149 | 7.2 | 34 | 65 | 169 | 8.0 | 49 | 65 | 
| 610 | 10000 | 137 | 6.7 | 41 | 65 | 163 | 8.0 | 32 | 65 | 187 | 9.0 | 46 | 65 | 
| 611 | 12000 | 162 | 7.7 | 55 | 65 | 194 | 9.2 | 43 | 65 | 216 | 10.5 | 44 | 65 | 
| 712 | 15000 | 195 | 9.6 | 36 | 65 | 242 | 11.8 | 45 | 65 | 276 | 13.2 | 60 | 65 | 
| 812 | 18000 | 231 | 11.2 | 43 | 65 | 285 | 13.5 | 53 | 65 | 329 | 15.6 | 75 | 65 | 
| 813 | 20000 | 261 | 12.8 | 57 | 65 | 320 | 15.4 | 69 | 80 | 369 | 17.5 | 95 | 65 | 
| 915 | 25000 | 320 | 15.2 | 49 | 80 | 418 | 20.0 | 91 | 80 | 473 | 22.6 | 124 | 80 | 
| 1015 | 30000 | 402 | 19.0 | 47 | 65 | 496 | 24.0 | 61 | 65 | 564 | 27.4 | 88 | 80 | 
| 1313 | 35000 | 450 | 21.6 | 46 | 65 | 558 | 26.4 | 57 | 65 | 642 | 30.6 | 82 | 65 | 
| 1315 | 40000 | 508 | 24.8 | 47 | 65 | 662 | 32.0 | 85 | 80 | 750 | 35.8 | 115 | 65 | 
| 1515 | 45000 | 570 | 27.0 | 51 | 65 | 748 | 35.6 | 94 | 80 | 852 | 41.6 | 137 | 65 | 
| 1417 | 50000 | 646 | 30.6 | 69 | 80 | 836 | 40.0 | 128 | 80 | 946 | 45.0 | 174 | 65 | 
| 1520 | 60000 | 816 | 38.8 | 50 | 80 | 984 | 48.0 | 53 | 80 | 1084 | 52.0 | 51 | 65 | 
| 1720 | 70000 | 948 | 46.4 | 55 | 80 | 1144 | 56.0 | 55 | 80 | 1252 | 60.0 | 52 | 80 | 
| 1722 | 80000 | 996 | 48.0 | 37 | 80 | 1248 | 59.2 | 48 | 80 | 1448 | 68.8 | 69 | 80 | 
| 1626 | 90000 | 1168 | 55.6 | 54 | 80 | 1444 | 68.8 | 69 | 80 | 1664 | 79.2 | 98 | 80 | 
| 1826 | 100000 | 1300 | 61.2 | 60 | 80 | 1620 | 77.2 | 80 | 80 | 1852 | 88.0 | 110 | 80 | 
| 1852 | 200000 | 2600 | 122.4 | 54 | 80 | 2888 | 137.6 | 69 | 80 | 3704 | 176 | 98 | 80 | 
| 3652 | 400000 | 5200 | 244.8 | 54 | 80 | 5776 | 275.2 | 69 | 80 | 7408 | 352 | 98 | 80 | 
Note:
■ Temperature of cooled inlet water: 7°C; temperature drop 5°C.
■ Fresh air conditions for standard cooling operation: dry/wet bulb temperature of inlet air: 34°C/28°C.
■ Coils are copper pipes with aluminum fins (12 fins/inch). EK can provide coils with 8~14 fins/inch.
|   | 
| Horizontal / Vertical Modular Residential Air Handling Units With 4 - 8 Row Images | 
 4 / 6 / 8 Row Double Skin Return Air Handling Units For Schools / Hospitals
                                                                                    
                        
                        
                        
                                                            4 / 6 / 8 Row Double Skin Return Air Handling Units For Schools / Hospitals
                                                    
                        
                     High Efficiency Ceiling Hanging Double Skin Air Handling Unit 12-754KW
                                                                                    
                        
                        
                        
                                                            High Efficiency Ceiling Hanging Double Skin Air Handling Unit 12-754KW
                                                    
                        
                     Vertical Cabinet Type Chilled Water Return Air Handling Unit 23-429KW
                                                                                    
                        
                        
                        
                                                            Vertical Cabinet Type Chilled Water Return Air Handling Unit 23-429KW
                                                    
                        
                     50 mm PU Insulation Double Skin Modular Fresh Air Handling Unit With Heat
                                                                                    
                        
                        
                        
                                                            50 mm PU Insulation Double Skin Modular Fresh Air Handling Unit With Heat
                                                    
                        
                     Double Skin Clean Room AHU Return Air Handling Units Indoor Installation
                                                                                    
                        
                        
                        
                                                            Double Skin Clean Room AHU Return Air Handling Units Indoor Installation
                                                    
                        
                     Double Skin 1/2 Rows Heating Coil 7-1300kw Custom Air Handling Units Ith 30/50
                                                                                    
                        
                        
                        
                                                            Double Skin 1/2 Rows Heating Coil 7-1300kw Custom Air Handling Units Ith 30/50
                                                    
                        
                     Airport installation modular AHUs with KRUGER fan VFD max 800 tons
                                                                                    
                        
                        
                        
                                                            Airport installation modular AHUs with KRUGER fan VFD max 800 tons
                                                    
                        
                     Humidifying HVAC Air Handling Unit With Backward Fan High ESP
                                                                                    
                        
                        
                        
                                                            Humidifying HVAC Air Handling Unit With Backward Fan High ESP
                                                    
                        
                     Floor Standing Direct Expansion Air Handling Unit With Condenser 30000-60000m3h
                                                                                    
                        
                        
                        
                                                            Floor Standing Direct Expansion Air Handling Unit With Condenser 30000-60000m3h
                                                    
                        
                     100000m3/H Plug Fan Modular Air Handling Units For Hospital
                                                                                    
                        
                        
                        
                                                            100000m3/H Plug Fan Modular Air Handling Units For Hospital